Nonin Onyx® Vantage 9590

Fingertip Pulse Oximeter

The Nonin Onyx Vantage 9590 is a compact, lightweight fingertip pulse oximeter designed to measure and display functional oxygen saturation of arterial hemoglobin (%SpO2) and pulse rate in both well-perfused and poorly perfused patients. It is intended for adult and pediatric

spot-checking on digits (including fingers, thumbs, and toes) across multiple care environments such as hospitals, clinics, long-term care facilities, skilled nursing facilities, EMS services, and home healthcare.

Reliable Performance

The device provides accurate readings across diverse skin pigmentations and maintains reliability even under low perfusion conditions.

Exclusive Features

Powered by Nonin PureSAT® technology, the Onyx Vantage 9590 delivers quick, precise SpO2 and pulse rate measurements.

Lasting Value

The unit offers up to 6,000 spot checks using two AAA batteries and comes with a 4-year warranty, supporting long-term use in clinical and home settings.

Durability Built for Demanding Use

Engineered for resilience, the Onyx Vantage 9590 is designed to withstand 50 drops from a one-meter height. With high battery efficiency and strong construction, it provides dependable value for both clinicians and patients.

Nonin PureSAT® Technology

The fingertip pulse oximeter produces fast, accurate, and cost-effective spot checks for pediatric and adult patients. PureSAT® automatically adapts to patient conditions, ensuring stable readings even in challenging measurement environments.

Accurate and Inclusive Pulse Oximetry

Unregulated devices may show inconsistent readings for individuals with darker skin tones or low perfusion. Since 1986, Nonin has focused on developing accurate, validated fingertip oximeters suitable for a broad range of skin pigmentations.

Technical Specifications
Measurement Ranges

Oxygen Saturation Display Range: 0% to 100% SpO2

Pulse Rate Display Range: 18 to 321 BPM

Declared Accuracy — Finger & Thumb (Non-Motion)

The tables below show Arms values measured using the Onyx Vantage 9590 in a clinical study in non-motion conditions.

Decade Oxygen Saturation (Arms)

70–80% ±2

80–90% ±2

90–100% ±2

70–100% ±2

This graph shows plots of the error (SpO2 – SaO2) by SaO2 using the 9590 with a linear regression fit and upper 95% and lower 95% limits of agreement. Each sample data point is identified by subject from a clinical study in non-motion conditions.

Declared Accuracy — Toe (Non-Motion)

Decade Oxygen Saturation (Arms)

70–80% ±2

80–90% ±3

90–100% ±3

70–100% ±3

(This graph shows plots of the error (SpO2 – SaO2) by SaO2 using the 9590 with a linear regression fit and upper 95% and lower 95% limits of agreement. Each sample data point is identified by subject from a clinical study using toes in non-motion conditions.)

Low Perfusion Accuracy

SpO2 Low Perfusion Accuracy (Arms*) 70 to 100% ±2 digits

Pulse Rate Declared Accuracy Range (Arms*): 20 to 250 BPM ±3 digits

Low Perfusion Pulse Rate Declared Accuracy Range (Arms*): 40 to 240 BPM ±3 digits

Measurement Wavelengths & Output Power

- Red: 660 nm @ 0.8 mW max average

- Infrared: 910 nm @ 1.2 mW max average

Useful for clinicians performing photodynamic therapy.

Environmental Conditions
Temperature

- Operating: -5 °C to 40 °C (23 °F to 104 °F)

- Storage/Transport: -40 °C to 70 °C (-40 °F to 158 °F)

Warm-up from storage:

– 3 minutes from -40 °C to -5 °C

– 5 minutes from 70 °C to 40 °C

Humidity

- Operating: 10% to 90% non-condensing

- Storage/Transport: 10% to 95% non-condensing

Altitude & Pressure

- Operating Altitude: Up to 4,000 m (13,123 ft)

- Hyperbaric Pressure: Up to 4 atmospheres

Power & Battery Life

- Two new alkaline AAA batteries

- Approximate runtime: 6,000 spot checks or 36 hours continuous operation

- Storage life: 12 months

Classification

- Degree of Protection: Type BF-Applied Part

- Ingress Protection: IP32

- Mode of Operation: Continuous

This device complies with ISO 10993-1 and is not made with natural rubber latex.

±1 Arms represents roughly 68% of measurements at zero bias.

Frequently Asked Questions

1. Can this device be used on both adults and pediatrics?

- Yes. It is intended for adult and pediatric spot checks on digits with a thickness of 0.3–1.0 inch (0.8–2.5 cm).

2. How long can I wear this device continuously?

- The Onyx Vantage 9590 is recommended for short-term spot-checking and not for settings where motion is expected or where monitoring exceeds 30 minutes.

Standard delivery:

Orders are typically processed within 1-2 business days and delivered within 3-5 business days. Delivery may be delayed during weekends or public holidays.

Shipping charges:
  • Orders from 0$ to 149$: shipping fee 10$.
  • Orders 150$ and above. Free shipping.
International shipping:

Currently, we do not offer international shipping.

Shipping issue and support:

If you experience any delays, damage, or missing items, please contact us immediately at +6593633572. We're here to ensure your shopping experience remains smooth and satisfactory.

Similar Products

Explore other devices and masks that may suit different clinical scenarios, patient preferences or care settings.
Nonin Sensors - 8000S

Nonin Sensors - 8000S

8000SS (Small), 8000SM (Medium), 8000SL (Large)

View Product Details
View Product Details
Nonin Sensors - 8000A

Nonin Sensors - 8000A

8000AA (Adult), 8000AP (Pediatric)

View Product Details
View Product Details