Nonin Model 7500

Description

Nonin Model 7500 Pulse Oximeter is a lightweight, portable pulse oximeter delivering accurate SpO₂ and pulse rate monitoring with Hybrid Averaging™ and PureSAT® technology, supporting reliable clinical decisions across hospital, homecare, and transport settings.

Category:
Oximetry & monitoring
Model 7500
Pulse Oximeter

The Nonin Model 7500 Pulse Oximeter provides caregivers with accurate oximetry information¹, supporting timely and confident clinical decisions when it matters most.

Equipped with Nonin Hybrid Averaging™, the Model 7500 reduces the impact of sudden SpO₂ fluctuations caused by motion artifacts or other transient conditions, while maintaining the rapid response associated with Standard/Fast Averaging. This helps minimise nuisance alarms, improve actionability, and support patient and caregiver confidence.

Lightweight, compact, and portable, the Model 7500 is suitable for monitoring infant, pediatric, and adult patients across a wide range of clinical and homecare environments. Its durable construction supports frequent and repeated use.

Key Features
Easy to Use

Multiple indicators support reliable readings, including a colour-coded pulse strength bar graph, pulse quality indicator, and sensor fault indicator.

Durable Design

Built to withstand continued heavy and repeated use in clinical and homecare settings.

Powerful Battery

Operates on AC line power or an internal battery, providing up to 16 hours of operation with a 4-hour recharge.

Internal Memory

Stores up to 70 hours of recorded data for review.

Flexible Alarms

Includes patient security mode and user-defined default settings to support customised patient configurations.

Pulse Strength Bar Graph

A colour-coded bar graph and saturation-related audible tone provide at-a-glance assessment at each pulse.

Pulse Quality Indicator

Identifies motion or signal quality changes that may require sensor site adjustment.

PureSAT® Technology

Uses intelligent pulse-by-pulse filtering to deliver precise oximetry measurements.

Versatile Use

Can operate as a standalone device or interface with other equipment.

Accuracy for Peace of Mind

The Model 7500 includes a selectable Hybrid Averaging option that reduces nuisance alarms related to brief desaturations caused by motion or other transient factors. This feature supports focused clinical response and may reduce unnecessary emergency visits.

PureSAT® and PureLight® Technologies

The Model 7500 incorporates advanced Nonin technologies, including PureSAT® pulse oximetry for intelligent signal filtering and PureLight® sensor technology combined with a bright LED display and large screen for clear visibility.

Reliable Data for Quality Care

For both clinical and at-home monitoring, dependable and easy-to-use equipment is essential. The Model 7500 delivers responsive measurements across a wide range of patient conditions, from hospital to home environments.

Accessories

- 7500 Carrying Case — 6031-000

- Analog Cable (AMI Monitor) — 6181-001

- Serial Output Cable — 5994-001

- Universal Extension Cable (1 m) — 6083-001

- Universal Extension Cable (3 m) — 6083-003

- Universal Extension Cable (6 m) — 6083-006

- Universal Extension Cable (9 m) — 6083-009

- Right Angle Connector — 3408-000

- Deluxe Tabletop Stand — 3668-100

- Pole Mount Clamp — 110708-001

Model 7500 Specifications
Display Ranges

SpO₂: 0–100%

Pulse Rate: 18–321 BPM

Displays

- Pulse Quality: LED, amber

- Sensor Alarm: LED, amber

- Pulse Strength Bar Graph: LED, tri-colour segments

- Alarm Indicator: LED, bi-colour

- Alarm Silenced: LED, amber

- Numeric Display: 3-digit, 7-segment LEDs, green

- Low Battery Indicator: LED, amber

Accuracy – Sensors

Declared accuracy for compatible sensors is available in Nonin’s Sensor Accuracy document.

Audio Levels

- Alarm Volume: High 75 dBA / Low 63 dBA

- Informational Tone: High 67 dBA / Low 55 dBA

Measurement Wavelengths & Output Powerᵃ

Red: 660 nm @ 0.8 mW maximum average

Infrared: 910 nm @ 1.2 mW maximum average

Memory

Up to 70 hours (continuous operation)

Environmental Conditions
Temperature

- Operating: 0 °C to 40 °C (32 °F to 104 °F)

- Storage/Transport: −40 °C to 70 °C (−40 °F to 158 °F)

- Warm-up: 6 minutes (−40 °C to 0 °C)

- Cool-down: 23 minutes (70 °C to 40 °C)

Humidity

- Operating: 10–90% non-condensing

- Storage/Transport: 10–95% non-condensing

Altitude

- Operating: Up to 4,000 m (13,123 ft)

- Hyperbaric Pressure: Up to 4 atmospheres

ᵃ Useful for clinicians performing photodynamic therapy.

Power Requirements

- Mains: 100–240 VAC, 50–60 Hz

- Internal Battery: 7.2 V NiMH battery pack

- Operating Life: Minimum 16 hours (fully charged)

- Storage Life: Minimum 21 days

- Recharge Time: Maximum 4 hours

Physical Characteristics

- Dimensions: 219 mm (W) × 92 mm (H) × 142 mm (D)

- Weight: ~900 g (2 lbs) with battery

Warranty

3 years

Standards & Classification

- ANSI/AAMI ES60601-1

- CAN/CSA-C22.2 No. 60601-1

- Protection: Class II (AC power), internally powered (battery)

- Applied Part: Type BF

- Mode of Operation: Continuous

- Ingress Protection: IP33

Analog Outputs

- SpO₂: 0–1 VDC (0–100%), 1.27 VDC (out of track)

- Pulse Rate: 0–1 VDC (0–300 BPM), 1.27 VDC (out of track)

- Event Marker: 0 V (no event), 1 V (event)

- Accuracy: ±2% SpO₂, ±5% Pulse Rate

- Load Current: 2 mA maximum

Troubleshooting

User-Defined Defaults

Create New Defaults (Patient Security Off)

1. Scroll settings using Limits

2. Adjust with + / –

3. Press Limits after each change

4. Scroll to end (“Π Π”)

5. Hold Alarm Silence, then press Limits

6. Display shows “DEF ON”

Return to Factory Defaults

1. With unit on, hold Alarm Silence

2. Press –

3. Display shows “dEF OFF”

4. Power cycle device

Patient Security Mode

Turn On

1. Scroll settings

2. Adjust with + / –

3. Press Limits

4. Scroll to end

5. Power off

6. Hold Alarm Silence while powering on

7. Display shows “SEC ON”

Turn Off

1. Power off (hold 3 seconds)

2. Hold Alarm Silence, then Limits, then Power

3. Display shows “SEC OFF”

Data Collection & Transfer

Recording begins automatically when powered on

Only sessions >1 minute are stored

Download to PC (Patient Security Off)

1. Power off

2. Connect using 7500SC cable

3. Open nVision software

4. Hold +, press Power (“PLA bac” displayed)

5. Device signals completion

Clear Memory

1. Scroll to “CLr No”

2. Press + (“Yes”)

3. Confirm with Limits

4. Select “dEL YES”

5. Confirm (“dnE CLr”)

Error Codes

Code Description

E01 Speaker failure

E02 Sound communication sync error

E03 Watchdog / NAK communication error

E04 System check failure

E05 Parameter memory error

E06 OEM III communication failure

Standard delivery:

Orders are typically processed within 1-2 business days and delivered within 3-5 business days. Delivery may be delayed during weekends or public holidays.

Shipping charges:
  • Orders from 0$ to 149$: shipping fee 10$.
  • Orders 150$ and above. Free shipping.
International shipping:

Currently, we do not offer international shipping.

Shipping issue and support:

If you experience any delays, damage, or missing items, please contact us immediately at +6593633572. We're here to ensure your shopping experience remains smooth and satisfactory.

Similar Products

Explore other devices and masks that may suit different clinical scenarios, patient preferences or care settings.
Nonin Sensors - 8000S

Nonin Sensors - 8000S

8000SS (Small), 8000SM (Medium), 8000SL (Large)

View Product Details
View Product Details
Nonin Sensors - 8000A

Nonin Sensors - 8000A

8000AA (Adult), 8000AP (Pediatric)

View Product Details
View Product Details
Nonin Sensors - 8000J

Nonin Sensors - 8000J

8000J (Adult), 8008J (Infant), 8001J (Neonatal)

View Product Details
View Product Details