Nonin 8000A reusable finger clip pulse oximetry sensors provide fast, accurate SpO₂ and pulse rate readings using PureLight® and PureSAT® technologies, designed for short-term monitoring in adult and pediatric patients.
The Nonin 8000A Reusable Finger Clip Pulse Oximetry Sensors are designed for short-term monitoring and spot checks in environments where the risk of cross-contamination is low. Built with Nonin PureLight® sensor technology and PureSAT® signal processing, the 8000A Series provides consistent, accurate readings from patient to patient and sensor to sensor.
PureSAT uses intelligent, pulse-by-pulse filtering to ensure accurate measurements, including in patients with darker skin tones.
- Available in two patient-specific models:
- 8000AA for Adult Patients (>30 kg / >66 lbs)
- 8000AP for Pediatric Patients (10–40 kg / 22–88 lbs)
The sensor delivers near-instant oxygen saturation and pulse rate measurements as soon as it is applied.
PureLight LEDs are engineered to deliver specific wavelengths and light intensities without secondary emissions. This eliminates variation across patients and sensors, ensuring consistent and dependable measurements.
Independent laboratory testing comparing the Nonin 8000AA to competitive “Nonin-compatible” finger clip sensors (Envitec, Unimed, and Cables & Sensors) demonstrated that the 8000AA offered the highest durability among the products tested.
Range Oxygen Saturation (Arms*) Motion Oxygen Saturation (Arms*)
70–100% ±2 ±3
70–80% ±2 ±3
80–90% ±2 ±3
90–100% ±2 ±2
- SpO₂: 70–100% ±2 digits (Arms*)¹
-Pulse Rate: 18–300 BPM ±3 digits (Arms*)¹
- Pulse Rate Low Perfusion: 40–240 BPM ±3 digits (Arms*)¹
- Operating: –20 °C to 50 °C (–4 °F to 122 °F)
- Storage/Transport: –40 °C to 70 °C (–40 °F to 158 °F)
- SpO₂: 70–100% ±2 digits (Arms*)¹
- Standard: 40–240 BPM ±3 digits (Arms*)¹
- Motion Accuracy: 40–250 BPM ±5 digits (Arms*)¹
- Low Perfusion Accuracy: 40–240 BPM ±3 digits (Arms*)¹
- Operating: –20 °C to 50 °C (–4 °F to 122 °F)
- Storage/Transport: –40 °C to 70 °C (–40 °F to 158 °F)
- Operating: 10% to 95% non-condensing
- Storage/Transport: 10% to 95% non-condensing
*±1 Arms represents 68% of the population at zero bias.
Additional accuracy and performance information is available in the operator’s manual CD.
Accuracy specifications are based on Nonin PureSAT® SpO₂ and PureLight® sensor technologies.
For combined oximeter/sensor specifications, refer to the specific oximetry system manual.
Range tested with Nonin PureSAT® SpO₂ technology.
- Red: 660 nm @ 3 mW nominal
- Infrared: 910 nm @ 3 mW nominal
Useful for clinicians performing photodynamic therapy.
- Complies with ISO 10993
Not made from natural rubber latex
Orders are typically processed within 1-2 business days and delivered within 3-5 business days. Delivery may be delayed during weekends or public holidays.
Currently, we do not offer international shipping.
If you experience any delays, damage, or missing items, please contact us immediately at +6593633572. We're here to ensure your shopping experience remains smooth and satisfactory.

Nonin Sensors - 8000S
8000SS (Small), 8000SM (Medium), 8000SL (Large)

Nonin Sensors - 8000J
8000J (Adult), 8008J (Infant), 8001J (Neonatal)